Your chromatography assistant

Your lab assistant, always on hand.

For chromatography and mass spectrometry. Get answers and fix everyday problems with instant support, without waiting for a field engineer or an email reply.

TroubleshootingTOGA analyzer
On the TOGA analyzer, the CO₂ and acetylene peaks are gone. What could it be?

The most likely cause is valve 2 switching to ON too late: the molecular sieve is still in line when CO₂ and acetylene leave the first column, so both are trapped on it. Check the valve 2 event time and move the switch earlier, before CO₂ reaches the sieve.

Expected chromatogram · FID + methanizer
representative
starting point · adjust the event time on the instrument

Which technique would you like to explore today?

Pick a technique and get answers built for it, each with its own knowledge base. For mass spectrometry, you work with GC-MS, LC-MS and IC-MS.

GCGas
HPLCLiquid
ICIons
MSMassesGC-MS · LC-MS · IC-MS

Why use it

Solve it before you open a ticket.

Most everyday questions don’t need a site visit. With ChromAssistant, you get the answer right away and try to fix the problem in the lab.

01

Answers right away

Describe the problem and get guidance on the spot, any time of day.

02

Everyday questions answered

Questions like which port goes to the vent, or why a peak disappeared from the chromatogram, don’t need a site visit.

03

Visits only when needed

When the problem is hardware, the field engineer is still the way to go. You can handle setup and operation questions before opening a ticket.

ChromAssistant Assistant

Tools for everyday lab work.

Virtual assistant

Ask anything about the technique you chose, including valve systems.

How do I shorten my HPLC run?Why does my LC-MS lose signal in matrix?Which eluent should I use for anions?When do I switch valve 1?

Troubleshooting

Solve problems step by step: a missing peak, a rising baseline, noise or a flame that won’t ignite.

Method development

Develop a new analysis or optimize one that’s already running, with backflush and heart-cut on valve systems.

Instruments

Register your lab instruments and get answers tailored to your system.

Lab 2 GCGas line GC

My chromatograms

The chromatograms you imported, organized by technique.

Build and visualize the valve map.

Build your analyzer’s valve system, follow the gas path in every position and simulate the separation to see when each compound elutes. It works offline, and your files stay on your machine.

  • Checks that every flow path is complete, port by port, in every valve position
  • Simulates each compound’s elution and shows when the valve can switch without cutting a peak
  • Shows which compounds are lost if the switch comes too early or too late
  • Suggests the connections when you don’t have the system drawing at hand
  • Load your instrument’s valve map and simulate

Suggested connections are verified by simulation. Check the physical port on the instrument before assembly.

Biogas2 valves · TCD
Valve 1 · OFFValve 2 · OFF
Simulated chromatogramTCD
active pathsampleinactive

What you can solve remotely.

Much of what becomes a service call today can be solved with a conversation: rising pressure on the HPLC, an unstable baseline in ion chromatography, signal dropping on the LC-MS or a peak missing on the GC.

Plans

Plans that fit the size of your company.

We have plans for a single user, for the lab team and for field service teams. Talk to sales and get a proposal for your case.

Your lab’s support, on demand.

Book a demo and see the platform and the Map Builder at work on a real question from your lab.